流水中に設置したシート状熱交換器の熱交換特性と農業用水路への設置方法
https://doi.org/10.24514/00001151
https://doi.org/10.24514/000011514f6382df-6061-4788-9506-933386c4a06a
名前 / ファイル | ライセンス | アクション |
---|---|---|
nire-bulletin003_03.pdf (2.9 MB)
|
© 国立研究開発法人 農業・食品産業技術総合研究機構
National Agriculture and Food Research Organization, Japan |
Item type | 紀要論文01 / Departmental Bulletin Original Article(1) | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
公開日 | 2019-03-07 | |||||||||||
タイトル | ||||||||||||
タイトル | 流水中に設置したシート状熱交換器の熱交換特性と農業用水路への設置方法 | |||||||||||
タイトル | ||||||||||||
タイトル | Heat Exchange Performances of Sheet Type Heat Exchanger submerged in Water Flow and Installation Method to an Agriculture Irrigation Canal | |||||||||||
言語 | en | |||||||||||
言語 | ||||||||||||
言語 | jpn | |||||||||||
キーワード | ||||||||||||
主題Scheme | Other | |||||||||||
主題 | シート状熱交換器 | |||||||||||
キーワード | ||||||||||||
主題Scheme | Other | |||||||||||
主題 | 水熱源 | |||||||||||
キーワード | ||||||||||||
主題Scheme | Other | |||||||||||
主題 | ヒートポンプ | |||||||||||
キーワード | ||||||||||||
主題Scheme | Other | |||||||||||
主題 | 農業用水路 | |||||||||||
キーワード | ||||||||||||
主題Scheme | Other | |||||||||||
主題 | 水理実験 | |||||||||||
キーワード | ||||||||||||
言語 | en | |||||||||||
主題Scheme | Other | |||||||||||
主題 | Sheet type heat exchanger | |||||||||||
キーワード | ||||||||||||
言語 | en | |||||||||||
主題Scheme | Other | |||||||||||
主題 | Water-source heat pump | |||||||||||
キーワード | ||||||||||||
言語 | en | |||||||||||
主題Scheme | Other | |||||||||||
主題 | Irrigation canal | |||||||||||
キーワード | ||||||||||||
言語 | en | |||||||||||
主題Scheme | Other | |||||||||||
主題 | Hydraulic model test | |||||||||||
資源タイプ | ||||||||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||||||||
資源タイプ | departmental bulletin paper | |||||||||||
ID登録 | ||||||||||||
ID登録 | 10.24514/00001151 | |||||||||||
ID登録タイプ | JaLC | |||||||||||
著者 |
後藤, 眞宏
× 後藤, 眞宏× 奥島, 里美× 三木, 昂史
WEKO
2059
× 高杉, 真司× 舘野, 正之× 小間, 憲彦× 木村, 繁男× 小松, 信義 |
|||||||||||
抄録 | ||||||||||||
内容記述タイプ | Abstract | |||||||||||
内容記述 | The sheet type heat exchanger was set in the full-scale hydraulic model in imitation of an agriculture irrigation canal and the experimental data of heat exchange performances were collected under the different conditions of hydraulic and installation methods. The heat exchange performances were evaluated by heat transfer coefficient that divided a square measure of a heat exchange capable by the heat transfer coefficient, which is an amount of heat transfer between the heat transfer liquid and the surrounding water flow, per a unit temperature difference between them and per a unit area of heat exchanger. The maximal heat transfer coefficient in water flow showed 0.255kW/(K・m2). The performance was higher than 0.017kW/(K・m2) of the same exchanger installed underground and 0.01kW/(K・m2) of slinky-type heat exchanger installed underground. The heat transfer coefficient was increased with increase in the speed in water flow, and there was little influence by the increase in hear transfer liquid. Sheet type heat exchanger integrated with reticulated expanded metal was devised to prevent the damage from trash and the sheet from being deflected. A high heat transfer coefficient was provided by being unified with sheet type heat exchanger integrated with reticulated expanded metal although it decreased by approximately 10%. The heat transfer coefficient on 110mm gap between sheet and side wall was the biggest and more than heat transfer coefficient 0.21kW/(K・m2) were measured. The blocking board installed at the edge of upper reaches of the expanded metals was effective from the viewpoint of prevention of trash adhesion. |
|||||||||||
抄録 | ||||||||||||
内容記述タイプ | Abstract | |||||||||||
内容記述 | 農業用水路を模した実規模水理模型にシート状熱交換器を設置して,水理条件や設置方法の違いによる熱交換特性を計測した。熱交換特性は,熱交換器と流水の温度差 1K 当たりの熱交換量を熱交換可能な面積で除した値である熱通過率を用いて評価した。流水条件下での最大の熱通過率は 0.255kW/(K・m2)で,土中設置の 0.017kW/(K・m2),スリンキー式の 0.01kW/(K・m2)よりも高い性能を示した。熱通過率は水路内流速の増加に伴って増加し,熱媒流量の増加による影響は少ない。熱交換器を網目状のエキスパンドメタルと一体化させて,流下物から保護し撓みなく設置する方法を考案した。エキスパンドメタルと一体化することで熱通過率は約 10%低下するものの,高い熱通過率が得られた。側壁間隔との関係では 110mm の時の熱通過率が最も大きく,熱通過率 0.21kW/(K・m2)以上が計測された。上流端のエキスパンドメタルに遮断板を設置することはゴミ付着防止の観点から有効である。 | |||||||||||
書誌情報 |
農研機構研究報告 農村工学研究部門 en : Bulletin of the NARO, Rural Engineering 巻 3, p. 29-42, 発行日 2019-03-30 |
|||||||||||
出版者 | ||||||||||||
出版者 | 国立研究開発法人 農業・食品産業技術総合研究機構 | |||||||||||
出版者 | ||||||||||||
出版者 | National Agriculture and Food Research Organization (NARO) | |||||||||||
ISSN | ||||||||||||
収録物識別子タイプ | ISSN | |||||||||||
収録物識別子 | 2432-7883 | |||||||||||
DOI | ||||||||||||
関連タイプ | isIdenticalTo | |||||||||||
識別子タイプ | DOI | |||||||||||
関連識別子 | 10.24514/00001151 | |||||||||||
著者版フラグ | ||||||||||||
出版タイプ | VoR | |||||||||||
出版タイプResource | http://purl.org/coar/version/c_970fb48d4fbd8a85 |